Skip to main content
Jul 05, 2026•Field Service

Winter Is Coming — Prevent ESP Freeze Damage

Water trapped inside a pump during transport or storage can fracture bearings, deform diffusers, and break impellers — prevention measures for cold-weather operations.

J
James BritvarEngineer

Cold Weather Is a Pump Killer

As colder temperatures approach, remember that ESP pumps are highly vulnerable to freeze damage if any water remains trapped inside during transport or storage in freezing conditions.

When fluid freezes inside a pump, it can fracture tungsten carbide bearings, deform diffusers, and break impellers, leading to premature failure.

Do not attempt to thaw frozen equipment on location — hidden damage cannot be detected during pre-check inspections or assembly. Return affected pumps to the shop for inspection and replacement.

Prevention Measures

  • ✅ After testing, suppliers shall fill pumps with 100% glycol (or equivalent) before shipment.
  • ✅ Field personnel should verify shaft rotation and axial travel upon delivery.
  • ✅ The same applies to capillary tubing. If the CT line cannot be pumped through prior to deployment, it should be rejected.

Following these steps will help ensure equipment reliability and prevent costly failures during cold-weather operations.