Reusing ESP Cable with Confidence: Inspection and Handling Best Practices

ESP cable is the single most expensive component of an onshore installation — field-proven inspection and handling practices that let you re-run it without premature failures.

J
James BritvarEngineer

Your Most Expensive Component

ESP cable is the single most expensive component of any onshore installation. For unconventional wells, operators are spending approximately $7.00 per foot for 8,000–10,500 feet of cable — that's a whopping $56,000–$73,500 for a new reel. One great thing about cable is that it can be reused if the condition passes inspection.

The Problem with Reuse

Which brings us to the problem: How do you maintain good cable condition for subsequent ESP runs after it's been 10,500 feet deep in a hot, corrosive, and deviated well? Furthermore, how do you know for sure that used cables have the integrity for another install without failing prematurely?

Proper handling is crucial — excess bending, pinching, or contact with sharp materials can compromise insulation beneath the armor.

A Field Inspection Case

We recently had the opportunity to participate in a cable inspection led by Graham Breakey. This project precipitated when the operator found that the most common cause of short run failure was reused cable grounding downhole. The task was to ensure that best practices are being applied during used cable workover procedures before being commissioned for installation.

Post-Run Inspection Best Practices

While there are numerous variables involved in re-running cable, a good place to start is with the post-run inspection. Industry best practice dictates the following for working cable:

  • Inspect both sides. Ensure both sides of used cable are always visually inspected, which will require spooling both directions at least.
  • Ground open legs during Hi-Pot testing to better isolate any fault in the subject phase.
  • Minimize bending when manipulating leads during the splice procedure to prevent compromising insulation.
  • Secure the pothead 6–8 inches above the housing for newly worked cable to prevent direct tension on the pothead.
  • Store reels on concrete or another solid surface to prevent sinking into the ground.

Document and Verify in the Field

Documenting guidelines for cable handling that align with company-specific expectations will ensure that all cable inspections provide the best chance for success on used cables. It is also recommended to witness equipment handling in the field on installations and pulls to mitigate potential for damage and uphold long-term cable integrity.

The findings will bolster procedures and ensure that cable will last as long as possible, furthermore increasing confidence in re-used cable.